What Gauge Wire Do I Need For A 20 Amp Breaker?

How far can you run 12 gauge wire on a 20 amp circuit?

For a 20 amp, you _must_ use 12 gauge to start with, 14 gauge doesn’t handle a 20 amp fuse at all.

A 12 gauge wire is typically good for 15 amp at 100 feet.

For your 160 feet, they suggest a 6 gauge..

Is it OK to mix 12 and 14 gauge wire?

Anyway, the first subject is a bit touchy because it makes it difficult to perform an inspection when all of the wires coming into the panel are 12 but many of the circuits have 14 in them too. There is nothing against code mixing wire size for these circuits as long as the OCPD matches the smallest wire.

How long can you run 12 gauge wire?

The following are the maximum lengths of cable you can use while still maintaining a 3 percent voltage drop for the given wire size (AWG) and circuit voltage….For 120-volt circuits:14 AWG50 feet12 AWG60 feet10 AWG64 feet8 AWG76 feet6 AWG94 feetOct 20, 2019

What is 14 gauge wire used for?

building wire14 – Wire12 – Wire6 – WireRecommended ForRecommended ForRecommended ForCommon residential wiring: Light fixtures, household receptacles.Common residential wiring: Light fixtures, household receptacles, small appliances.Large household appliances: Central air conditioning, electric furnace.4 more rows

Is it OK to use 12 gauge wire on a 15 amp circuit?

However, 12-gauge wire is acceptable on both 15- and 20-amp circuits, so some electricians use it exclusively when wiring a house.

Can you use 14 gauge wire with a 20 amp breaker?

NEC 240.4(D)(3) states that 14 AWG must be protected at 15A. You can not use 14 AWG anywhere on a circuit that has a 20A breaker. If you are putting 15 amp receptacles on a 20 amp circuit with 12 gauge wire, then you MUST use the screw terminals, not the back stab terminals. … Just use the side terminals.

Will 12 gauge wire carry 20 amps?

12-gauge wire is the next size larger and is allowed to carry up to 20 amps. As a result, the amp rating of a circuit breaker has the following relation to the wire size that has been chosen. A 20-amp breaker is never* allowed to run any circuit whose wires (anywhere on the circuit) are 14-gauge.

How many outlets can I put on a 20 amp circuit?

10 receptaclesOne rule of thumb is to assign a maximum draw of 1.5 amps to each receptacle, which allows for 10 receptacles on a 20-amp circuit.

What happens if wire gauge is too big?

The more power and equipment you have, the larger the wire needs to be. … If too small of a size is used, the wire could melt because of the large amount of current flowing through it compared to how much the cables can handle. The smaller the wire diameter, the higher the resistance there will be to the flow of energy.

Is a bigger gauge wire better?

The lower the gauge number, the thicker the wire. Thicker wire presents less resistance to current flow. Relative thickness of wire gauges, drawn to scale (not actual size). Thick wire (12 or 14 gauge) is recommended for long wire runs, high power applications, and low-impedance speakers (4 or 6 ohms).

Can I use 12 gauge wire for lights?

Yes, it is okay to use 12-2 cable to supply lighting fixtures. The other answer indicates that it even with 12-2 you have to use a 15A breaker for lighting circuits which is not strictly correct. If the entire circuit is 12AWG (other than fixture wires), then a 20A breaker may be used.

Can I use 8 gauge wire on a 20 amp circuit?

RULES OF THUMB. Many techs will repeat these rules of thumb and rely on them in all circumstances: “Twelve-gauge wire is good for 20 amps, 10-gauge wire is good for 30 amps, 8-gauge is good for 40 amps, and 6-gauge is good for 55 amps,” and “The circuit breaker or fuse is always sized to protect the conductor [wire].”

How many outlets can a GFCI protect?

A standard GFCI will protect up to 20 amps, drawn from any combination of receptacles, either the built-in one or any number of additional ones connected to its load terminals.

How many outlets can you put on a 14 2 wire?

14–2 wire is allowed for a 15 Amp circuit, and at 120 Volts, 15 Amps x 120 volts = 1800 volt-amperes. So that would allow ten (10) receptacles, you would probably derate that to eight (8) for an 80% safety factor.